novAA® 400 P – fully automated compact spectrometer for flame, graphite
furnace and hydride technology.
Features:
8 lamp changer for maximum automation and
sample throughput
Single and double beam available – D2 background
correction
Integrated RFID Tool for working with coded
lamps
Integrated super lamp power supply for best
analytical performance
Integrated High-end Vision Tool for best
observation and control of sample injection and sample drying in the graphite
tube
Direct analysis of solid samples
A unique furnace design
The transverse-heated graphite furnace is a
must where optimum atomization conditions and high sample throughput are
required simultaneously. This clearly superior concept has, for a number of
years, been successfully employed in all Analytik Jena graphite furnace AAS
systems. It guarantees uniform temperature all along the optical axis
throughout the tube and eliminates memory and condensation effects that occur
at the cooler tube ends of conventional, longitudinally heated graphite tubes.
Lower atomizing temperatures prolong tube life. Problem-free analysis of
low-volatility elements (e.g., vanadium, molybdenum), and the direct analysis
of solid samples are possible.
Marked improvement in accuracy
Transverse-heated graphite tubes
considerably diminish many chemical interferences and therefore matrix effects.
As a consequence, your analyses are almost memory-free.
Cost-efficient analyses
To save operating costs, you can choose
between two types of tubes: The platform tube allows you to determine all
elements with just one tube – no need to change tubes during a multi-element
analysis. For simple applications, the low-cost wall tube is the best choice.
Time-saving and amazingly easy
The transverse-heated tube design makes
tube change and adjusting the sampler pipetting tip easier than ever before.
Automated flame technology – high precision and speed
Fast analysis, automated dilution, reliable
quality monitoring, all with uncomplicated handling, are a must. Meeting these
requirements with ease, the novAA® is bound to become an indispensable routine
spectrometer for element analysis.
Autosampler – maximum sample throughput
Autosamplers make your routine analysis of
standards and samples almost fully automatic. Integrated in the overall concept
of the instrument, either sampler can be simply hung directly into the sample
compartment. This saves space and minimizes tubing lengths – the best way to
prevent contamination.
A wide variety of accessories
Accessories such as the Segmented Flow Star
(SFS) or the Scraper help you facing the challenges of complex matrices in
flame analysis. In addition to the standard flame technique the software
controlled SFS for injection mode operation is convincing by:
Easy operation of
samples with high salt or acid content
Stable burner conditions guaranteed by continuous rinsing and
constant temperature conditions
Automatic metering of smallest sample volumes
The Scraper is an intelligent, automatic,
software-controlled cleaning device:
For the nitrous oxide burner head for trouble-free work over a long
period
For continuous and reproducible measuring cycles in routine analysis
Before each sample measurement and calibration the slot is cleaned –
or best reproducible results